Ciência Rural (Dec 2012)

Um novo clorofilômetro para estimar os teores de clorofila em folhas do capim Tifton 85 A new chlorophyll meter to estimate chlorophyll contents in leaves of Tifton 85 bermudagrass

  • Élio Barbieri Junior,
  • Roberto Oscar Pereyra Rossiello,
  • Rosani Valéria Marcelina Matoso Silva,
  • Roberta Cristiane Ribeiro,
  • Mirton José Frota Morenz

Journal volume & issue
Vol. 42, no. 12
pp. 2242 – 2245

Abstract

Read online

O propósito deste trabalho foi verificar o desempenho de um novo clorofilometro portátil, em parcelas experimentais vegetadas com o capim-Tifton 85 (Cynodon spp.). Para tal, foi utilizado um experimento de curta duração, em que três doses de N (0,75 e 150kg de N ha-1) foram combinadas com quatro datas de amostragem (8, 16, 24 e 28 dias após um corte de uniformização). As análises foram feitas em lâminas da folha mais nova totalmente expandida. Os teores das clorofilas a, b e a+b foram quantificados espectrofotometricamente após a extração com acetona 80%, enquanto que o clorofilômetro forneceu os correspondentes valores de Índice de Clorofila Falker (ICF). As leituras do aparelho foram sensíveis tanto às doses de N quanto às datas de amostragem. Foram obtidas correlações positivas entre ambos os métodos de quantificação (clorofila a: r=0,646; b: r=0,797; e total: r=0,721), que evidenciaram a utilidade desse novo clorofilometro na determinação indireta dos teores de clorofila foliar no capim-Tifton 85.The purpose of this research was to evaluate the performance of a new portable chlorophyll meter in the indirect determination of chlorophyll contents in Tifton 85 bermudagrass leaves. In a field trial of short duration, three N doses (0, 75 and 150kg ha-1) were combined with four sampling dates (8, 16, 24 e 28 days after a cut for sward uniformity) in completely randomized blocks, with treatments arranged in a split-plot design. Analyses were performed in the youngest fully expanded leaf blade. Contents of chlorophylls a, b and total were quantified spectrophotometrically, after extraction with acetone 80%, while chlorophyll meter readings, expressed as Falker Chlorophyll Index (FCI) units, provided the same information. Chlorophyll meter readings were sensitive to both N rates and sampling dates. It were obtained significant positive correlations between both methods (chlorophyll a: r=0.646, chlorophyll b: r=0.797 and for total chlorophyll: r=0.721). It was concluded that this new chlorophyll meter constitutes an appropriate tool for the indirect determination of foliar chlorophyll contents in Tifton 85 pastures.

Keywords