Guoji Yanke Zazhi (Apr 2024)

Accuracy of four formulas in predicting diopter of intraocular lens implanted in high myopia cataract eyes

  • Qiu Wei,
  • Wei Qingquan,
  • Gong Yingying,
  • Jiang Yanyun

DOI
https://doi.org/10.3980/j.issn.1672-5123.2024.4.27
Journal volume & issue
Vol. 24, no. 4
pp. 641 – 645

Abstract

Read online

AIM: To evaluate the accuracy of the formulas, including Haigis, SRK/T, Holladay 1, and Holladay 2, in predicting the diopter of the intraocular lens implanted in high myopia cataract patients.METHODS: Prospective study. A total of 168 cases(168 eyes)of age-related cataract with an axial length(AL)≥26 mm who were treated in our hospital from August 2017 to November 2021 were selected. According to the preoperative AL measured by IOL Master 700, the patients were divided into five groups, including 37 cases(37 eyes)in group A with 26 mm≤AL<27 mm, 34 cases(34 eyes)in group B with 27 mm≤AL<28 mm, 42 cases(42 eyes)in group C with 28 mm≤AL<29 mm, 28 cases(28 eyes)in group D with 29 mm≤AL<30 mm, and 27 patients(27 eyes)in group E with AL ≥ 30 mm. Subjective refraction was performed at 3 mo postoperatively, and the mean numerical error(MNE)and mean absolute error(MAE)of each formula for predicting diopters were calculated.RESULTS: The MNE and MAE of the Haigis and Holladay 2 formulas were relatively less in each group, and MNE and MAE did not significantly increase with the growth of the axial length. However, the MAE and MNE of the SRK/T and Holladay 1 formulas significantly increased with the growth of the axial length, with the MNE and MAE of the Holladay 1 formula increasing more significantly in groups C, D, and E.CONCLUSION: For patients with age-related cataract, with an axial length of ≥26 mm, the accuracy of predicting the diopter of the intraocular lens using the Haigis and Holladay 2 formulas were higher.

Keywords