Abstract

Read online

This paper presents a series of economic efficiency studies comparing three different investment variants: without energy storage, with energy stored in batteries and hydrogen installation with a PEM fuel cell stack for a location in Poland. To reach a target, the current solar potential in Poland, the photovoltaic (PV) productivity, the capacity of the energy storage in batteries as well as the size of the hydrogen production system were calculated. The solar potential was determined using archival meteorological data and the Krieg estimation method. A laboratory scale PV system (1 kW) was used to estimate the decrease in real solar installation power during the last 10 years of operation. All analyses were made for a 100 kW photovoltaic array located in Poland using static and dynamic methods of investment project assessment, such as Simply Bay Back Period (SPBP) or Net Present Value (NPV). The results showed that the SPBP amounted to 8.8 years and NPV 54,896 € for non-storage systems. Whereas, for systems with energy stored the economic indexes were, as follow: SPBP = never, NPV = 183,428 € for batteries and SPBP = 14.74 years, NPV = 22,639 € for hydrogen/fuel cell installation. Storage in hydrogen is more advantageous than batteries due to the smaller investment outlays.