Applied Sciences (Sep 2024)

Investigation of the Effects Caused by Current Interruption Devices of Lithium Cells at High Overvoltages

  • Jan Haß,
  • Christina Schieber,
  • Florian Meilinger,
  • Yash Kotak,
  • Serkan Sevinc,
  • Philipp Lang,
  • Hans-Georg Schweiger

DOI
https://doi.org/10.3390/app14188238
Journal volume & issue
Vol. 14, no. 18
p. 8238

Abstract

Read online

A faulty voltage measurement can lead to the overcharging of a Li-Ion cell, resulting in gas formation and heating inside the cell, which can trigger thermal runaway. To mitigate this risk, cylindrical cells are equipped with a Current Interrupt Device (CID), which functions as a pressure relief valve, disconnecting the electrical circuit within the cell when internal pressure rises. However, this disconnection causes the cell to suddenly become highly resistant, posing a significant issue in series-connected cells. In such configurations, a portion or even the entire system voltage may drop across the disconnected cell, substantially increasing the likelihood of an electric arc. This arc could ignite any escaping flammable gases, leading to catastrophic failures. In a series of tests conducted on three different cell chemistries—NMC (Nickel Manganese Cobalt), NCA (Nickel Cobalt Aluminum), and LFP (Lithium Iron Phosphate)—it was found that the safe operation of the CID cannot be guaranteed for system voltages exceeding 120 V. Although comparative tests at double the nominal cell voltage did not exhibit the same behavior, these findings suggest that current safety standards, which recommend testing at double the nominal voltage, may not adequately address the risks involved. The tests further revealed that series connections of cells with CIDs are inherently dangerous, as, in the worst-case scenario, the entire system voltage can be concentrated across a single cell, leading to potential system failure.

Keywords