Journal of Clinical Ophthalmology and Research (Jan 2020)

Sutureless scleral fixated three-piece intraocular lens in the management of dislocated capsular bag–capsular tension ring–intraocular lens complex

  • Naresh Babu Kannan,
  • Olukorede O Adenuga,
  • Rajan P Renu,
  • Kim Ramasamy

DOI
https://doi.org/10.4103/jcor.jcor_107_17
Journal volume & issue
Vol. 8, no. 1
pp. 35 – 37

Abstract

Read online

A number of techniques have been described in the management of capsular bag (CB)–capsular tension ring (CTR)-intraocular lens (IOL) dislocation, including pars plana vitrectomy (PPV) with explantation of the CTR and IOL through a corneal section and exchange with a scleral suture-fixated IOL or anterior chamber IOL, and repositioning of the CB–CTR–IOL complex with scleral suture fixation. We describe a technique of managing CB–CTR–IOL dislocation which involves PPV with CTR removal and sutureless scleral fixation of the same three-piece IOL. This was performed in two patients with good visual outcome and well-centered IOLs postoperatively.

Keywords