Micromachines (Mar 2017)

The Optimization of a Microfluidic CTC Filtering Chip by Simulation

  • Huan Li,
  • Jianfeng Chen,
  • Wenqiang Du,
  • Youjun Xia,
  • Depei Wang,
  • Gang Zhao,
  • Jiaru Chu

DOI
https://doi.org/10.3390/mi8030079
Journal volume & issue
Vol. 8, no. 3
p. 79

Abstract

Read online

The detection and separation of circulating tumor cells (CTCs) are crucial in early cancer diagnosis and cancer prognosis. Filtration through a thin film is one of the size and deformability based separation methods, which can isolate rare CTCs from the peripheral blood of cancer patients regardless of their heterogeneity. In this paper, volume of fluid (VOF) multiphase flow models are employed to clarify the cells’ filtering processes. The cells may deform significantly when they enter a channel constriction, which will induce cell membrane stress and damage if the area strain is larger than the critical value. Therefore, the cellular damage criterion characterized by membrane area strain is presented in our model, i.e., the lysis limit of the lipid bilayer is taken as the critical area strain. Under this criterion, we discover that the microfilters with slit-shaped pores do less damage to cells than those with circular pores. The influence of contact angle between the microfilters and blood cells on cellular injury is also discussed. Moreover, the optimal film thickness and flux in our simulations are obtained as 0.5 μm and 0.375 mm/s, respectively. These findings will provide constructive guidance for the improvement of next generation microfilters with higher throughput and less cellular damage.

Keywords