Journal of Orthopaedic Surgery and Research (Nov 2021)

Computer-assisted cannulated screw internal fixation versus conventional cannulated screw internal fixation for femoral neck fractures: a systematic review and meta-analysis

  • Qing-hao Cheng,
  • Peng-biao Li,
  • Ting-ting Lu,
  • Shi-fang Guo,
  • Wen-fei Di,
  • Ke-hu Yang,
  • Yao-wen Qian

DOI
https://doi.org/10.1186/s13018-021-02806-7
Journal volume & issue
Vol. 16, no. 1
pp. 1 – 14

Abstract

Read online

Abstract Objective To compare the effects between computer-assisted and traditional cannulated screw internal fixation on treating femoral neck fracture. Methods The search was conducted in Embase, Pubmed, Web of Science, Cochrane Library, China National Knowledge Infrastructure (CNKI) and Wanfang Database from the beginning to August 2020. RevMan5.4 software, which was provided by the International Cochrane Group, was used for the meta-analysis comparing the differences in operation time, intraoperative bleeding volume, fluoroscopy frequency, fracture healing time, total drilling times, Harris score, fracture healing rate, and femoral head necrosis rate between computer-assisted and traditional methods groups. Results A total of 1028 patients were included in 16 studies. Primary outcome indicators: Compared with the traditional method group, the computer-assisted group had less operative time (2RCTs, P < 0.00001; 8 non-RCTs, P = 0.009; Overall, P < 0.00001), intraoperative bleeding (1 RCTs, P < 0.00001; 9non-RCTs, P < 0.00001; Overall, P < 0.00001), femoral head necrosis rate (1 RCT, P = 0.11;7 non-RCTs, P = 0.09; Overall, P = 0.02) and higher Harris scores (1 RCT, P < 0.0001; 9 non-RCTs, P = 0.0002; Overall, P < 0.0001), and there were no significant differences in fracture healing rate between the two groups (5 non-RCTs, P = 0.17). Secondary outcomes indicators: The computer-assisted group had a lower frequency of intraoperative fluoroscopy and total number of drills compared with the traditional method group, while there was no significant difference in fracture healing time. Conclusion Compared with the traditional hollow screw internal fixation on the treatment of femoral neck fracture, computer-assisted percutaneous cannulated screw fixation can shorten the operation time and improve the operation efficiency and reduce the X-ray injury of medical staff and help patients obtain a better prognosis. Therefore, computer-assisted percutaneous cannulated screw fixation is a better choice for the treatment of femoral neck fracture. Study registration PROSPERO registration number CRD42020214493.