E3S Web of Conferences (Jan 2021)
Water Quality Assessment of West Tarum Canal for Drinking Water Supply
Abstract
West Tarum Canal (WTC) is a canal that drains raw water from the Jatiluhur Dam. Nearly 81% of the raw water for drinking water used by Jakarta’s people comes from this canal. However, various land uses such as agriculture, industry, settlements, and infrastructure development impact WTC’s water quality. This research aims to assess WTC’s water quality in 2016-2020 based on water quality standards set by the Government and using the STORET method. The results of this research indicate that the concentrations of TDS (142-351 mg/L), Fe (0.1-0.15 mg/L), Mn (0.03-0.1 mg/L) are meet the standards, while DO (3.6-4.9 mg/L), BOD (4-10 mg/L), COD (13-30 mg/L) are not meet the standards. Almost all monitoring points have pH values between 5.75-7.68 that are meet the standards. The STORET score of WTC is from -26 to -38 with an average of -30, which indicates that WTC’s water quality is moderately polluted. Water contamination in WTC will burden the drinking water processing and ultimately affect the community’s ability to pay for drinking water. This research also shows the need for integrated management of WTC from upstream to downstream and the need to increase collaboration between stakeholders in carrying out this management.