Journal of Orthopaedic Surgery and Research (Nov 2023)
A new arthroscopic repair technique for triangular fibrocartilage complex using an intracapsular suture: an outside-in transfer all-inside repair
Abstract
Abstract Background Arthroscopic repair is a promising, minimally invasive surgical technique for patients with Palmer type 1B peripheral triangular fibrocartilage complex (TFCC) tears. Although several arthroscopic techniques are effective for repairing Palmer type 1B TFCC tears, some shortcomings remain. So, we report an arthroscopic repair technique for the treatment of Palmer type 1B Atzei class 1 TFCC tears using an intracapsular suture: an outside-in transfer all-inside repair. Methods A retrospective analysis of 38 Palmer type 1B TFCC injury patients admitted to our hospital were randomly divided into 2 groups. The group A was sutured from the outside to the inside, with a total of 21 cases; the group B was sutured with the new arthroscopic repair technique, with a total of 17 cases. Observe and compare the VAS scores and modified Mayo wrist function scores of all patients before 3, and 6 months after the operation and evaluate the incidence of thread knots in patients with different treatment methods. The methodology was performed an arthroscopic intracapsular suture using an outside-in transfer, all-inside repair technique, which is a modified method of the outside-in and all-inside technique using the needle of a 10-mL sterile syringe, for Palmer type 1B TFCC tears. A No. 2 polydioxanone suture was threaded through the needle and entered the wrist joint. Next, the needle was withdrawn carefully along the suture to the proximal tear ulnar surface of the TFCC and penetrated the TFCC, exiting the articular cavity surface of the ulnar side of the torn TFCC. Finally, arthroscopic knotting was performed. Results This new treatment was as effective as the previously arthroscopic techniques and had the advantages of no additional incision and decreased risk of operation-related complications. The incidence of thread knots in the group A (28.57%) was significantly higher than that in the group B (0%), and the difference was statistically significant (P = 0.024). There was no significant difference in VAS score and modified Mayo wrist function scores between the two groups (P > 0.05). Conclusions The outside-in transfer, the all-inside repair technique is suitable for Palmer type 1B Atzei class 1 TFCC tears. We recommend this technique as a useful alternative to the conventional methods of repairing Palmer type 1B TFCC tears.
Keywords