Buildings (May 2024)
Fortifying Slab Resilience against Touch-Off Explosions: Integration of Innovative Stud Reinforcements and Computational Analysis
Abstract
Explosions, once limited to military and accidental contexts, now occur frequently due to advances in warfare, local disputes, and global conflicts. Recent incidents, like urban bombings, emphasize the urgent need for infrastructure to withstand explosions. Slabs, critical in architectural frameworks, are vulnerable to explosive forces due to their slimness, making them prime targets for sabotage. Scholars have explored various strategies to fortify slabs, including the use of advanced materials like CFRP laminates/strips, steel sheets and ultra-high-strength concrete, along with reinforcement techniques such as two-mesh and diagonal reinforcements. A novel approach introduced in current research involves integrating vertical short bars, or studs, to enhance slab resilience against touch-off explosions. The aim of this research endeavor is to assess the impact of studs and their utilization in bolstering the anti-contact-blast capabilities of a concrete slab. To achieve this goal, a specialized framework within the ABAQUS/Explicit 2020 software is employed for comprehensive analysis. Initially, a conventionally reinforced slab devoid of studs serves as the benchmark model for numerical validation, facilitating a comparative assessment of its anti-contact-blast effectiveness against the findings outlined by Zhao and colleagues in 2019. Following successful validation, six additional distinct slab models are formulated utilizing sophisticated software, incorporating studs of varying heights, namely, 15 mm and 10 mm. Each configuration encompasses three distinct welding scenarios: (i) integration with upper-layer bars, (ii) attachment to bottom-layer bars, and (iii) connection to both upper- and bottom-layer bars. The comparative merits of the slabs are evaluated and deliberated upon through the examination of diverse response parameters. The research revealed that the incorporation of studs within slabs yielded notable enhancements in blast resistance. Specifically, taller studs demonstrated exceptional resilience against deformation, cracking, and perforation, while also diminishing plastic damage energy. Particularly noteworthy was the superior performance observed in slabs with studs welded to both upper and lower layers of re-bars. This highlights the critical significance of both the integration of studs and their precise positioning in fortifying structural integrity against blast-induced loadings.
Keywords