PLoS ONE (Jan 2015)

Anisotropic Smoothing Improves DT-MRI-Based Muscle Fiber Tractography.

  • Amanda K W Buck,
  • Zhaohua Ding,
  • Christopher P Elder,
  • Theodore F Towse,
  • Bruce M Damon

DOI
https://doi.org/10.1371/journal.pone.0126953
Journal volume & issue
Vol. 10, no. 5
p. e0126953

Abstract

Read online

To assess the effect of anisotropic smoothing on fiber tracking measures, including pennation angle, fiber tract length, and fiber tract number in the medial gastrocnemius (MG) muscle in healthy subjects using diffusion-weighted magnetic resonance imaging (DW-MRI).3T DW-MRI data were used for muscle fiber tractography in the MG of healthy subjects. Anisotropic smoothing was applied at three levels (5%, 10%, 15%), and pennation angle, tract length, fiber tract number, fractional anisotropy, and principal eigenvector orientation were quantified for each smoothing level.Fiber tract length increased with pre-fiber tracking smoothing, and local heterogeneities in fiber direction were reduced. However, pennation angle was not affected by smoothing.Modest anisotropic smoothing (10%) improved fiber-tracking results, while preserving structural features.