Безопасность информационных технологий (Oct 2016)

See laser testing at different temperatures

  • Alexander Anatolievich Novikov,
  • Aleksandr Aleksandrovich Pechenkin,
  • Aleksandr Innokent’evich Chumakov,
  • Alexey Olegovich Akhmetov,
  • Oleg Borisovich Mavritskii

Journal volume & issue
Vol. 23, no. 3
pp. 55 – 60

Abstract

Read online

The main problem for laser SEE testing at different temperatures is to determine correlation between laser pulse energy and LET. In the first approximation, LET values with the same laser pulse energy and different temperatures are directly proportional to the absorption coefficient of laser light in a semiconductor. Use of tabulated values could lead to errors and absorption coefficient should be determined for each sensitive volume of device under test (DUT). Temperature dependence of absorption coefficient could be determined using ionization response of DUT in power supply circuit under local laser irradiation. Using this approach a satisfactory correlation of ion and laser SEE test result was observed.