STAR Protocols (Jun 2021)
Cyclic uniaxial cell stretching in tissue culture using a LEGO®-based mechanical stretcher and a polydimethylsiloxane stretchable vessel
Abstract
Summary: Mechanical signals are essential for the regulation of many biological processes. Therefore, it has become paramount to account for these mechanical parameters when exploring biological processes. Here, we describe a protocol to apply cyclic uniaxial stretch on cells in culture using a LEGO®-based mechanical stretcher and a flexible custom-made polydimethylsiloxane culture vessel as well as validated downstream applications. While this system offers an out-of-the-box limited type of simulation, it provides a reliable and low-cost opportunity to perform cell stretching.For complete details on the use and execution of this protocol, please refer to Boulter et al. (2020).