Радиационная гигиена (Jul 2024)

Conservative assessment of external radiation dose for staff in the event of radionuclide flaw detection

  • S. Yu. Bazhin,
  • E. N. Shleenkova,
  • V. Yu. Bogatyreva

DOI
https://doi.org/10.21514/1998-426X-2023-17-2-76-85
Journal volume & issue
Vol. 17, no. 2
pp. 76 – 85

Abstract

Read online

The article proposes a new approach to assessing the effective doses of flaw detectorists performing flaw detection using portable radionuclide flaw detectors (gamma flaw detectors). The existing approach to assessing effective doses, based on the use of one individual dosimeter placed on work clothes in the chest area, is inadequate for the actual working conditions of exposure of flaw detectorists. Gamma flaw detectors contain a closed man-made source of ionizing radiation in their head, therefore, even in the non-working position, such flaw detectors pose a radiation hazard. When transporting and preparing gamma flaw detectors for work, the flaw detector operator is in close proximity to the radiation source. The irradiation geometry changing during the technological cycle when working with portable gamma flaw detectors at certain stages creates a sharply uneven irradiation of the flaw detectorist’s body. Therefore, after assessing the stages of the technological cycle, an option was proposed for a more conservative assessment of effective doses – to change the location of the individual dosimeter on the working clothes of the flaw detectorist, moving the individual dosimeter to the abdominal area. An anonymous study was carried out with the participation of 15 flaw detectorists; three individual dosimeters were displayed on their working clothes: two of them were experimental and were placed in the chest and abdomen; the third (a control dosimeter) was exposed for the quarter on the chest as part of constant individual dosimetric monitoring. In controlled anonymous measurements, the average effective dose, estimated from the readings of dosimeters exposed in the chest area, was equal to 0,95 mSv (median – 0,92 mSv, maximum value – 1,27 mSv). These values were compared with values obtained using dosimeters that were exposed to the abdomen, and the differences were significant (the average effective dose was 1,24 mSv (median – 1,22 mSv, maximum value – 1,78 mSv).

Keywords