E3S Web of Conferences (Jan 2019)
Analysis of the temperature distribution in the place of fixing the ventilated facade
Abstract
Designers more and more often choose facade systems with ventilated layers for external walls, especially in the case of new buildings. They are also used to modernize existing buildings. Mechanical connectors are a characteristic element of these constructions. Often, they are ignored in calculating the heat balance of rooms and the entire building. Because they pierce the thermal insulation layer they cause point thermal bridges. The influence of thermal point bridges, usually made of aluminum, i.e. a material with very high thermal conductivity, for heat transfer turns out to be significant. Such thermal bridges significantly increase heat losses through building partitions. This situation increases the heat demand in the rooms to compensate for the heat loss. The article presents the results of the analysis of the impact of mechanical fasteners in ventilated facade systems on heat transfer in the building envelope. The influence of various materials and constructional solutions on the thermal conditions in these walls was investigated.