Simulation of X-ray imaging property of halide lead perovskite scintillators
ZHANG Yuyu,
YANG Zhi,
SHENG Liang,
DUAN Baojun,
YAN Weipeng,
SONG Yan,
WANG Minqiang
Affiliations
ZHANG Yuyu
(Electronic Materials Research Laboratory (EMRL), Key Laboratory of Education Ministry; International Center for Dielectric Research (ICDR); Shaanxi Engineering Research Center of Advanced Energy Materials and Devices, School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China)
YANG Zhi
(Electronic Materials Research Laboratory (EMRL), Key Laboratory of Education Ministry; International Center for Dielectric Research (ICDR); Shaanxi Engineering Research Center of Advanced Energy Materials and Devices, School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China)
SHENG Liang
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024, China
DUAN Baojun
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024, China
YAN Weipeng
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024, China
SONG Yan
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024, China
WANG Minqiang
(Electronic Materials Research Laboratory (EMRL), Key Laboratory of Education Ministry; International Center for Dielectric Research (ICDR); Shaanxi Engineering Research Center of Advanced Energy Materials and Devices, School of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China)
BackgroundIn recent years, lead halide perovskite scintillators have received extensive attention in the field of X-ray imaging. Hard X-ray medical imaging in energy range of 20~120 keV using scintillator detectors, sensitivity and imaging spatial resolution are important performance indicators.PurposeThis study aims to explore X-ray imaging property of halide lead perovskite scintillators by simulation.MethodsFirst of all, 3D MAPbBr3 quantum dots/polystyrene and 2D PEA2PbBr4 quantum dots/polystyrene scintillators were taken as research objects. Then, simulation code Geant4 was employed to establish detector model and simulate the X-ray relative detection efficiency and imaging spatial resolution of lead halide perovskite quantum dots/polymer composite scintillators. Finally, the effect of energy and the ratio of perovskite quantum dot occupation on the resolution were explained by secondary electron motion.ResultsThe results show that increasing the thickness of the composite scintillator and the proportion of perovskite quantum dots can improve the relative detection efficiency whilst reducing the thickness and increasing the proportion of perovskite quantum dots can improve the spatial resolution. When the absorption efficiency reaches 99.5%, 80% of 3D MAPbBr3 quantum dots/polystyrene excited by 20 keV X ray obtain the same spatial resolution of 10 lp·mm-1 as CsI. When the incident energy increases to 50 keV, the spatial resolution of CsI is 8 lp·mm-1, while that of lead halide perovskite scintillators is less than 4 lp·mm-1.ConclusionsIt is shown by this study that lead halide perovskites have certain application potential in 20 keV low-energy X-ray medical imaging.