Biomedicines (Feb 2023)

First Live-Experience Session with PET/CT Specimen Imager: A Pilot Analysis in Prostate Cancer and Neuroendocrine Tumor

  • Lorenzo Muraglia,
  • Francesco Mattana,
  • Laura Lavinia Travaini,
  • Gennaro Musi,
  • Emilio Bertani,
  • Giuseppe Renne,
  • Eleonora Pisa,
  • Mahila Esmeralda Ferrari,
  • Uberto Fumagalli Romario,
  • Ottavio De Cobelli,
  • Nicola Fusco,
  • Francesco Ceci

DOI
https://doi.org/10.3390/biomedicines11020645
Journal volume & issue
Vol. 11, no. 2
p. 645

Abstract

Read online

Objective: to evaluate the feasibility of the intra-operative application of a specimen PET/CT imager in a clinical setting. Materials and methods: this is a pilot analysis performed in three patients who received an intra-operative administration of 68Ga-PSMA-11 (n = 2) and 68Ga-DOTA-TOC (n = 1), respectively. Patients were administrated with PET radiopharmaceuticals to perform radio-guided surgery with a beta-probe detector during radical prostatectomy for prostate cancer (PCa) and salvage lymphadenectomy for recurrent neuroendocrine tumor (NET) of the ileum, respectively. All procedures have been performed within two ongoing clinical trials in our Institute (NCT05596851 and NCT05448157). Pathologic assessment with immunohistochemistry (PSMA-staining and SSA immunoreactivity) was considered as standard of truth. Specimen images were compared with baseline PET/CT images and histopathological analysis. Results: Patients received 1 MBq/Kg of 68Ga-PSMA-11 (PCa) or 1.2 MBq/Kg of 68Ga-DOTA-TOC (NET) prior to surgery. Specimens were collected, positioned in the dedicated specimen container, and scanned to obtain high-resolution PET/CT images. In all cases, a perfect match was observed between the findings detected by the specimen imager and histopathology. Overall, the PET spatial resolution was sensibly higher for the specimen images compared to the baseline whole-body PET/CT images. Furthermore, the use of the PET/CT specimen imager did not significantly interfere with any procedures, and the overall length of the surgery was not affected using the PET/CT specimen imager. Finally, the radiation exposure of the operating theater staff was lower than 40 µSv per procedure (range 26–40 μSv). Conclusions: the image acquisition of specimens obtained by patients who received intra-surgery injections of 68Ga-PSMA-11 and 68Ga-DOTA-TOC was feasible and reliable also in a live-experience session and has been easily adapted to surgery daily practice. The high sensitivity, together with the evaluation of intra-lesion tumor heterogeneity, were the most relevant results since the data derived from specimen PET/CT imaging matched perfectly with the histopathological analysis.

Keywords