Korean Journal of Thoracic and Cardiovascular Surgery (Dec 2018)

Cuff Technique for Small-Diameter Vascular Grafts in the Systemic Arterial Circulation of the Rat

  • Sukki Cho,
  • In Hag Song

DOI
https://doi.org/10.5090/kjtcs.2018.51.6.423
Journal volume & issue
Vol. 51, no. 6
pp. 423 – 426

Abstract

Read online

This study determined the feasibility of the cuff technique for small-caliber vascular grafts in a rat model. A graft was implanted with the cuff technique or suture technique in a 1-cm segment of the abdominal aorta in 12 rats. The mean aortic clamp time was 29 minutes with the cuff technique and 44 minutes with the suture technique; the cuff technique was significantly shorter. Abdominal angiography at 1 week after implantation showed no significant stenosis in 9 rats, focal stenosis of the mid-portion of the graft in 1 rat with each technique, and total occlusion of the graft in 1 rat with the suture technique. We have successfully used the cuff technique for anastomosis for small-caliber vascular grafts in an animal model.

Keywords