BMC Anesthesiology (Aug 2024)

Cardiopulmonary crisis caused by bronchial blocker malposition in a patient with aberrant tracheal anatomy: a case report

  • Qiliang Song,
  • Zongming Jiang

DOI
https://doi.org/10.1186/s12871-024-02668-6
Journal volume & issue
Vol. 24, no. 1
pp. 1 – 5

Abstract

Read online

Abstract Background Double-lumen tubes (DLTs) and bronchial blockers (BBs) can be used to establish one-lung ventilation (OLV) for thoracic surgery. BBs are a good alternative when DLTs are not suitable or patients have difficult airways. However, BBs are more prone to malposition, leading to adverse events. Case presentation We present a 68-year-old male patient who was scheduled for thoracoscopic left lower lobectomy. The patient was not expected to have airway malformation preoperatively. When the DLT could not be inserted into the bronchus after general anesthesia induction, we used a BB to perform OLV. During surgery, malposition of the BB resulted in the development of an “incomplete balloon valve”, leading to a cardiopulmonary crisis. Conclusions Previewing chest computed tomography scans to assess the airway anatomy before thoracic surgery is essential. Three-dimensional reconstruction of the airway can provide a more intuitive assessment of airway anatomy. During OLV with BBs, we should pay attention to balloon malposition to prevent cardiopulmonary crises.

Keywords