Foods (Mar 2020)

Multiplex Recombinase Polymerase Amplification Assay for the Simultaneous Detection of Three Foodborne Pathogens in Seafood

  • Biao Ma,
  • Jiali Li,
  • Kai Chen,
  • Xiaoping Yu,
  • Chuanxin Sun,
  • Mingzhou Zhang

DOI
https://doi.org/10.3390/foods9030278
Journal volume & issue
Vol. 9, no. 3
p. 278

Abstract

Read online

Foodborne pathogens can cause foodborne illness. In reality, one food sample may carry more than one pathogen. A rapid, sensitive, and multiple target method for bacteria detection is crucial in food safety. For the simultaneous detection of Staphylococcus aureus, Vibrio parahaemolyticus, and Salmonella Enteritidis, multi-objective recombinase polymerase amplification (RPA) combined with a lateral flow dipstick (LFD) was developed in this study. The whole process, including amplification and reading, can be completed in 15 min at 37 °C. The detection limits were 2.6 × 101 CFU/mL for Staphylococcus aureus, 7.6 × 101 CFU/mL for Vibrio parahaemolyticus, and 1.29 × 101 CFU/mL for Salmonella Enteritidis. Moreover, colored signal intensities on test lines were measured by a test strip reader to achieve quantitative detection for Staphylococcus aureus (R2 = 0.9903), Vibrio parahaemolyticus (R2 = 0.9928), and Salmonella Enteritidis (R2 = 0.9945). In addition, the method demonstrated good recoveries (92.00%−107.95%) in the testing of spiked food samples. Therefore, the multiplex LFD-RPA assay is a feasible method for the rapid, sensitive, and quantitative detection of bacterial pathogens in seafood.

Keywords