Archives of Civil Engineering (Jun 2024)
Comparative analysis of the BFRP and steel reinforcement bars under fire conditions
Abstract
The FRP reinforcement gained importance due to high tensile strength, high durability and ecological friendliness [1–7]. Its usefulness as the internal or Near Surface Mounted reinforcement in bent concrete elements has already been proven. Though, in terms of the compressive behaviour of the bars and concrete elements incorporating them, there are still few experimental and numerical considerations, especially when high temperatures are considered. This article contains further considerations on the performance of concrete columns with BFRP main reinforcement in fire resistance tests on the basis of previously presented authors’ numerical analyses. Comparative analysis in terms of temperatures, deformations and stresses of concrete columns with BFRP and steel main reinforcement in fire resistance tests is presented by the example of two columns, for which also experimental investigations were performed. Also, a comparative analysis of stress-strain relations for BFRP, steel and concrete at temperatures up to 600°C is presented. It can be concluded that BFRP bars’ properties are strongly different when compressive and tensile performance is considered, especially at elevated temperatures. Tensile strength was higher for BFRP than steel at room temperature, but along with temperature growth, it came the other way (at around 600°C). The compressive strength of the BFRP bars was higher than the value for concrete, but only for temperatures lower than 200°C.
Keywords