Atmospheric Chemistry and Physics (Nov 2022)

Water vapour and ozone in the upper troposphere–lower stratosphere: global climatologies from three Canadian limb-viewing instruments

  • P. S. Jeffery,
  • K. A. Walker,
  • C. E. Sioris,
  • C. D. Boone,
  • D. Degenstein,
  • G. L. Manney,
  • G. L. Manney,
  • C. T. McElroy,
  • L. Millán,
  • D. A. Plummer,
  • N. J. Ryan,
  • P. E. Sheese,
  • J. Zou

DOI
https://doi.org/10.5194/acp-22-14709-2022
Journal volume & issue
Vol. 22
pp. 14709 – 14734

Abstract

Read online

This study presents upper troposphere–lower stratosphere (UTLS) water vapour and ozone climatologies generated from 14 years (June 2004 to May 2018) of measurements made by three Canadian limb-viewing satellite instruments: the Atmospheric Chemistry Experiment Fourier Transform Spectrometer (ACE-FTS), the Measurement of Aerosol Extinction in the Stratosphere and Troposphere Retrieved by Occultation (MAESTRO), and the Optical Spectrograph and InfraRed Imaging System (OSIRIS; ozone only). This selection of instruments was chosen to explore the capability of these Canadian instruments in representing the UTLS and to enable analysis of the impact of different measurement sampling patterns. The water vapour and ozone climatologies have been constructed using tropopause-relative potential temperature and equivalent-latitude coordinates in an effort to best represent the distribution of these two gases in the UTLS, which is characterized by a high degree of dynamic and geophysical variability. Zonal-mean multiyear-mean climatologies are provided with 5∘ equivalent latitude and 10 K potential temperature spacing and have been constructed on a monthly, seasonal (3-month), and yearly basis. These climatologies are examined in-depth for two 3-month periods, December–January–February and June–July–August, and are compared to reference climatologies constructed from the Canadian Middle Atmosphere Model 39-year specified dynamics (CMAM39-SD) run, subsampled to the times and locations of the satellite measurements, in order to evaluate the consistency of water vapour and ozone between the datasets. Specifically, this method of using a subsampled model addresses the impact of each instrument's measuring pattern and allows for the quantification of the influence of different measurement patterns on multiyear climatologies. This in turn permits a more consistent evaluation of the distributions of these two gas species, as assessed through the differences between the model and measurement climatologies. For water vapour, the average absolute relative difference between CMAM39-SD and ACE-FTS differed between the two versions of ACE-FTS by less than 8 %, while the MAESTRO climatologies were found to differ by 15 %–41 % from ACE-FTS, depending on the version of ACE-FTS and the season. When considering the ozone climatologies, those constructed from the two ACE-FTS versions agreed to within 2 % overall, and the OSIRIS ozone climatologies agreed with these to within 10 %. The MAESTRO ozone climatologies differ from those from ACE-FTS and OSIRIS by 30 %–35 % and 25 %, respectively, albeit with regions of better agreement within the UTLS. These findings indicate that this set of Canadian limb sounders yields generally similar water vapour and ozone distributions in the UTLS, with some exceptions for MAESTRO depending on the season and gas species.