Orthopaedic Surgery (Jun 2020)
Accuracy and Safety of Robot‐Assisted Drilling Decompression for Osteonecrosis of the Femoral Head
Abstract
Objective To investigate the safety and superiority of robot‐assisted femoral head drilling decompression in the treatment of femoral head necrosis. Methods A total of 63 patients who underwent borehole decompression of the femoral head in our hospital from January 2016 to March 2019 were recruited. Patients were divided into two groups for comparison according to surgical methods. In the robot‐assisted surgery group, there were 30 cases with 41 femoral heads. The conventional group had 33 cases and 46 femoral heads. All patients signed the consent form before the operation. The follow‐up time was 6 months. The incision lengths, operation times, intraoperative blood loss, intraoperative fluoroscopies, guide needle punctures, postoperative Harris scores, and postoperative complications of the two groups were compared. Results The incision length of the robot surgery group was 5.16 ± 0.41 cm, while that of the traditional surgery group was 7.42 ± 0.50 cm. The operation time of the robot surgery group was 46.99 ± 4.94 min, while that of the traditional surgery group was 55.01 ± 6.19 min. The fluoroscopy frequency of the robot surgery group was 10.50 ± 1.78 times, while that of the traditional surgery group was 17.91 ± 2.20 times. The intraoperative blood loss in the robotic surgery group was 20.62 ± 2.52 mL, while that in the conventional surgery group was 52.72 ± 3.39 mL. In the robot operation group, each femoral head guide needle was punctured three times, and the puncture was successful one time. The number of guided needle punctures in the traditional group was 8.02 ± 1.73. The difference between the two groups was statistically significant (P 0.05). In the traditional group, there was one case of incision infection and one case of femoral head collapse during follow‐up. In the robot group, there were no complications, such as incision infection and deep vein thrombosis. No collapse of the femoral head was found in the robot group during follow‐up. Conclusion The positioning system of the orthopaedic robot is an ideal method for the treatment of femoral head necrosis. This method has the advantages of simple operation, accurate drilling, a short operation time, less surgical trauma, less radioactivity, and good recovery of hip joint function.
Keywords