PLoS ONE (Jan 2020)
Sonographic measurement of normal common bile duct diameter and associated factors at the University of Gondar comprehensive specialized hospital and selected private imaging center in Gondar town, North West Ethiopia.
Abstract
BACKGROUND:The biliary tree is a three-dimensional system of channels that bile flows from the hepatocytes to the gallbladder and to the intestine. Size of the common bile duct (CBD) is a predictor of biliary obstruction and, therefore, its measurement is an important component of biliary system evaluation. Factors like age, height, weight, BMI, previous cholecystectomy, drugs, and type of imaging modality affect CBD diameter, but the duct significantly dilated due to obstructive biliary pathology. OBJECTIVE:To measure the normal CBD diameter and its association with age, sex, and anthropometric measurement at the University of Gondar Comprehensive Specialized Hospital and selected private imaging center, Gondar town, Northwest Ethiopia, 2019. METHODS AND MATERIALS:Institutional based cross-sectional study was conducted on 206 subjects without any history of hepatobiliary abnormality. The CBD measured at the proximal part just caudal to the porta hepatis. Descriptive analysis, student t-test, one way ANOVA, correlation and both bivariable and multivariable linear regression analysis were implemented. In bivariable linear regression variables with p-value, less than 0.2 were selected for multivariable analysis and in multivariable linear regression analysis variables with P-Value less than 0.05 were considered as statistically significant. RESULTS:The mean age of the study participants was 39.4 (range 18-87). The mean diameter of the CBD was 3.64mm 95%CI (3.52, 3.77), which ranges from 1.8 to 5.9 mm, with 65% of the participant having CBD diameter less than 4mm. The diameter of CBD significantly associated with age with a linear trend. The mean diameter in a rural area was greater than subjects living in an urban area. Independent t-test showed no statistically significant difference in CBD diameter between male and female subjects. CONCLUSION:The lower limit of the CBD diameter for this study was similar to most of the studies, but the upper limit was found to be slightly lower. The diameter was significantly associated with age along the linear trend and it was progressively increased from the lower age group onwards. The diameter of CBD did not show statistically significant association with any of the anthropometric measurement.