Archives of Electrical Engineering (Nov 2022)

Design methods for limiting rotor losses in a fractional slot PMSM motor with high power density

  • Tomasz Wolnik,
  • Szczepan Opach,
  • Łukasz Cyganik,
  • Tomasz Jarek,
  • Vojtech Szekeres

DOI
https://doi.org/10.24425/aee.2022.142119
Journal volume & issue
Vol. vol. 71, no. No 4
pp. 963 – 979

Abstract

Read online

Fractional slot PMSM motors enable high power density factors to be obtained provided that their electromagnetic circuit, appropriate mechanical structure and cooling system are properly designed, as well as when operating at a high frequency of power supply voltage (400–800 Hz) with high magnetic saturation and high current loads (approx. 12–15 A/mm2). Such operating conditions, especially in the case of fractional slot motors, may be the reason for excessive rotor losses, mainly in the rotor yoke and permanent magnets. One of the conditions for obtaining high values of continuous power of the motor is the reduction of these losses. This paper presents selected design methods for limiting the value of rotor losses with simultaneous consideration of their influence on other motor parameters. The analysiswas carried out for aPMSMmotor with an external rotorweighting approx. 10 kg and a maximum power of 50 kW at a rotational speed of 4 800 rpm.

Keywords