PLoS ONE (Jan 2021)

Comparison of pancreatic fat content measured by different methods employing MR mDixon sequence.

  • Xiaoyang Li,
  • Qiushi Yang,
  • Hang Ye,
  • Shuo Li,
  • Yuzhu Wang,
  • Wanjiang Yu

DOI
https://doi.org/10.1371/journal.pone.0260001
Journal volume & issue
Vol. 16, no. 11
p. e0260001

Abstract

Read online

ObjectiveTo compare the reliability of different methods for measuring fat content of pancreas by MR modified Dixon(mDixon) Sequence and accurately evaluate pancreatic fat in as simple a way as possible.MethodsThis is a retrospective study, 64 patients were included in this study who underwent abdominal MR scan that contained the mDixon sequence from June 2019 to May 2020(Included 7 patients with type 2 diabetes and 4 patients with impaired glucose tolerance (IGT), they were admitted to hospital through the obesity clinic set up by endocrine department, all of them were initially diagnosed and untreated). All of the 64 patients were scanned in 3.0T MR (Philips Ingenia II) due to their condition, 10-34 slice pancreas images were obtained, which were different from each other. Three different methods of measurement were employed by two observers using Philips Intellispace Portal software: (1) All images (whole-pancreas) measurement, the whole-pancreatic fat fraction (wPFF) was calculated by software. (2) Interval slices measurement, that is half-pancreatic slices fat fraction (hPFF) measured in the same way, fat fraction obtained by the interlayer assay was calculated. (3) As usual, the fat content of pancreatic head, body and tail fat was measured respectively, and in order to improve credibility, we also measured head、 body and tail in every layer, and its average value was taken. The elapsed time of the above different measurement methods was recorded. Intra-group correlation coefficient (ICC) was used to analyze the consistency of the measured data within and between observers. T-tests and Friedman tests were applied to compare the difference of measured values among groups.ResultsNo matter in normal person or diabetic or IGT, hPFF has shown good stability (ICChPFF = 0.988), and there was no significant difference compared with wPFF. But the average fat percentage composition of head, body and tail were significantly different from wPFF and hPFF (P ConclusionThe distribution of pancreatic fat is not uniform, the method of measuring half pancreas by interlayer data collection can reflect the fat content of the entire pancreas, this suggests that measuring 50% of the pancreas is sufficient, this method effectively saves time and effort without affecting the results, which may have a better clinical application prospect.