Clinical Ophthalmology (Sep 2011)
Influence of optic disc size on the diagnostic performance of macular ganglion cell complex and peripapillary retinal nerve fiber layer analyses in glaucoma
Abstract
Daniela Valença Cordeiro1, Verônica Castro Lima1,2, Dinorah P Castro1,3, Leonardo C Castro1,3, Maria Angélica Pacheco2, Jae Min Lee2, Marcelo I Dimantas2, Tiago Santos Prata1,21Department of Ophthalmology, Federal University of São Paulo, São Paulo, 2Hospital Medicina dos Olhos, São Paulo, 3Centro Brasileiro de Especialidades Oftalmológicas, Araraquara, BrazilAim: To evaluate the influence of optic disc size on the diagnostic accuracy of macular ganglion cell complex (GCC) and conventional peripapillary retinal nerve fiber layer (pRNFL) analyses provided by spectral domain optical coherence tomography (SD-OCT) in glaucoma.Methods: Eighty-two glaucoma patients and 30 healthy subjects were included. All patients underwent GCC (7 × 7 mm macular grid, consisting of RNFL, ganglion cell and inner plexiform layers) and pRNFL thickness measurement (3.45 mm circular scan) by SD-OCT. One eye was randomly selected for analysis. Initially, receiver operating characteristic (ROC) curves were generated for different GCC and pRNFL parameters. The effect of disc area on the diagnostic accuracy of these parameters was evaluated using a logistic ROC regression model. Subsequently, 1.5, 2.0, and 2.5 mm2 disc sizes were arbitrarily chosen (based on data distribution) and the predicted areas under the ROC curves (AUCs) and sensitivities were compared at fixed specificities for each.Results: Average mean deviation index for glaucomatous eyes was -5.3 ± 5.2 dB. Similar AUCs were found for the best pRNFL (average thickness = 0.872) and GCC parameters (average thickness = 0.824; P = 0.19).The coefficient representing disc area in the ROC regression model was not statistically significant for average pRNFL thickness (-0.176) or average GCC thickness (0.088; P ≥ 0.56). AUCs for fixed disc areas (1.5, 2.0, and 2.5 mm2) were 0.904, 0.891, and 0.875 for average pRNFL thickness and 0.834, 0.842, and 0.851 for average GCC thickness, respectively. The highest sensitivities – at 80% specificity for average pRNFL (84.5%) and GCC thicknesses (74.5%) – were found with disc sizes fixed at 1.5 mm2 and 2.5 mm2.Conclusion: Diagnostic accuracy was similar between pRNFL and GCC thickness parameters. Although not statistically significant, there was a trend for a better diagnostic accuracy of pRNFL thickness measurement in cases of smaller discs. For GCC analysis, an inverse effect was observed.Keywords: glaucoma, retinal nerve fiber layer, optical coherence tomography, ganglion cell complex