Journal of Orthopaedic Surgery and Research (Apr 2020)

The frequency of reduction loss after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device, and its effect on clinical and radiological results

  • Engin Çarkçı,
  • Ayşe Esin Polat,
  • Tahsin Gürpınar

DOI
https://doi.org/10.1186/s13018-020-01674-x
Journal volume & issue
Vol. 15, no. 1
pp. 1 – 7

Abstract

Read online

Abstract Background The aim of this study was to investigate the effect of reduction loss of more than 3 mm on clinical and radiological results after at least 2 years of follow-up after arthroscopic fixation of acute acromioclavicular joint dislocations using a double-button device. Methods Thirty-six patients who had acute ( 0.05). At the last follow-up, the mean Acromioclavicular Joint Instability (ACJI) score of group A was 84.4 ± 8, whereas it was 68.3 ± 8.3 for group B, and the difference was statistically significant (p < 0.01). Furthermore, the subjective evaluation and aesthetic subjective satisfaction values of group B were lower than group A (p < 0.01). Conclusions Reduction loss of more than 3 mm was observed in 25% of patients after arthroscopic fixation of acute acromioclavicular dislocations using a double-button device. Although this loss did not create a statistically significant difference in Constant scores, AC joint-specific tests such as ACJI, subjective evaluation, and aesthetic subjective satisfaction values were significantly impaired.

Keywords