World Journal of Surgical Oncology (Jun 2022)

Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study

  • Thanawin Wong,
  • Tanawat Pattarapuntakul,
  • Nisa Netinatsunton,
  • Bancha Ovartlarnporn,
  • Jaksin Sottisuporn,
  • Naichaya Chamroonkul,
  • Pimsiri Sripongpun,
  • Sawangpong Jandee,
  • Apichat Kaewdech,
  • Siriboon Attasaranya,
  • Teerha Piratvisuth

DOI
https://doi.org/10.1186/s12957-022-02682-3
Journal volume & issue
Vol. 20, no. 1
pp. 1 – 8

Abstract

Read online

Abstract Background Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is an established diagnostic procedure for solid pancreatic mass. However, the diagnostic yield between fine-needle aspiration (FNA) and fine-needle biopsy (FNB) remains unclear. We aimed to evaluate and compare the diagnostic yields between FNA and FNB using conventional FNA and Franseen needles of the same size 22-gauge needle, in patients with solid pancreatic mass who underwent EUS-TA without rapid onsite cytopathology evaluation (ROSE). Methods All cases of EUS-TA by FNA or FNB for solid pancreatic mass between January 2017 and October 2020 in a single-centre university hospital were retrospectively reviewed. All procedures were performed without an onsite cytologist. Before the endoscopist finished the procedure, macroscopic onsite evaluation (MOSE) was confirmed. The diagnostic yield and the average number of needle passes between FNB and FNA were then compared. Results A total of 151 patients (FNA, n = 77; FNB, n = 74) with solid pancreatic mass detected by cross-sectional imaging underwent EUS-TA. The mean age was 62.3 ± 12.8 years, with 88 (58.3%) males. Age, sex, mass location, tumour size and disease stage from imaging were not significantly different between the two groups. The diagnostic performance was higher in EUS-FNB (94.6%) than in EUS-FNA (89.6%). The mean number of needle passes was clearly fewer in FNB than in FNA (2.8 vs. 3.8, p < 0.001). The total procedure time was shorter in FNB (34.7 min) than in FNA (41 min). The adverse event rate between FNB and FNA was not significantly different. Conclusions The diagnostic yield of solid pancreatic mass was higher in FNB using the Franseen needle than in FNA using the conventional FNA needle in a centre where ROSE is unavailable, without serious adverse event. In addition, FNB had fewer needle passes and shorter total procedure time.

Keywords