Scientific Reports (Jan 2024)
Gender differences in cementless short stem total hip arthroplasty: significantly higher femoral lengthening in female patients
Abstract
Abstract Modern cementless short stems in total hip arthroplasty (THA) enable a precise reconstruction of the native pre-arthritic hip geometry. While gender differences have been reported for older generation straight hip stems, there are hardly reports regarding modern cementless short hip stems. Therefore, we aimed to evaluate the influence of gender differences in hip anatomy in cementless short stem THA. A total of 207 patients (109 females, 98 males) with unilateral THA and absence of contralateral joint space narrowing (Kellgren-Lawrence grade ≤ 2) were included. Acetabular height and offset as well as femoral height and offset were measured on pre- and 3-months-postoperative anteroposterior X-rays of the pelvis and compared to the contralateral hip. Additionally, implant position was evaluated on the postoperative radiograph. In male patients, the loss of acetabular offset was significantly greater than in females (p = 0.012), leading to a compensatory increase in femoral offset (p = 0.041). Femoral height discrepancy was significantly higher in females (p < 0.001), accounting for an increased global hip height discrepancy (p < 0.001). The mean acetabular anteversion was significantly greater in female patients (p < 0.001). Female patients are at higher risk of femoral lengthening in THA with a cementless short stem potentially caused by a further proximally conducted femoral neck osteotomy and show significantly higher cup anteversion angles. Therefore, surgeons should take special care to the level of neck resection and implant positioning in female patients.