Insights into Imaging (Nov 2021)

Limitations of cardiothoracic ratio derived from chest radiographs to predict real heart size: comparison with magnetic resonance imaging

  • Paulius Simkus,
  • Manuel Gutierrez Gimeno,
  • Audra Banisauskaite,
  • Jurate Noreikaite,
  • David McCreavy,
  • Diana Penha,
  • Monika Arzanauskaite

DOI
https://doi.org/10.1186/s13244-021-01097-0
Journal volume & issue
Vol. 12, no. 1
pp. 1 – 10

Abstract

Read online

Abstract Background Cardiothoracic ratio (CTR) in chest radiographs is still widely used to estimate cardiac size despite the advent of newer imaging techniques. We hypothesise that a universal CTR cut-off value of 50% is a poor indicator of cardiac enlargement. Our aim was to compare CTR with volumetric and functional parameters derived from cardiac magnetic resonance imaging (MRI). Methods 309 patients with a chest radiograph and cardiac MRI acquired within a month were reviewed to assess how CTR correlates with multiple cardiac MRI variables: bi-ventricular EDV (absolute and indexed to body surface area), EF, indexed total heart volume and bi-atrial areas. In addition, we have also determined CTR accuracy by creating multiple ROC curves with the described variables. Results All cardiac MRI variables correlate weakly but statistically significantly with CTR. This weak correlation is explained by a substantial overlap of cardiac MRI parameters in patients with normal and increased CTR. For all variables, CTR was only mildly to moderately better than a chance to discriminate cardiac enlargement (AUC 0.6–0.7). Large CTR values (> 55%) are specific but not sensitive, while low CTR values ( 55%) are likely indicative of true heart chamber enlargement. Low CTRs (< 45%) are likely indicative of normal heart size.

Keywords