Micromachines (May 2024)
Design and Fabrication of Biosensor for a Specific Microbe by Silicon-Based Interference Color System
Abstract
In this paper, one of the great challenges faced by silicon-based biosensors is resolved using a biomaterial multilayer. Tiny biomolecules are deposited on silicon substrates, producing devices that have the ability to act as iridescent color sensors. The color is formed by a coating of uniform microstructures through the interference of light. The system exploits a flat, RNA-aptamer-coated silicon-based surface to which captured microbes are covalently attached. Silicon surfaces are encompassed with the layer-by-layer deposition of biomolecules, as characterized by atomic force microscopy and X-ray photoelectron spectroscopy. Furthermore, the results demonstrate an application of an RNA aptamer chip for sensing a specific bacterium. Interestingly, the detection limit for the microbe was observed to be 2 × 106 CFUmL−1 by visually observed color changes, which were confirmed further using UV-Vis reflectance spectrophotometry. In this report, a flexible method has been developed for the detection of the pathogen Sphingobium yanoikuyae, which is found in non-beverage alcohols. The optimized system is capable of detecting the specific target microbe. The simple concept of these iridescent color changes is mainly derived from the increase in thickness of the nano-ordered layers.
Keywords