Robust Tracking Control of a Three-Phase Charger under Unbalanced Grid Conditions

  • Chivon Choeung,
  • Meng Leang Kry,
  • Young Il Lee

DOI
https://doi.org/10.3390/en11123389
Journal volume & issue
Vol. 11, no. 12
p. 3389

Abstract

Read online

This paper presents a robust control technique for three-phase chargers under unbalanced grid conditions. The control method consists of inner-loop robust grid-current control and outer-loop proportional integral control for constant current (CC) and constant voltage (CV) control. A dual-current control for the inner-loop positive and negative sequence is employed to eliminate the unbalanced current caused by the grid so that a constant current and voltage can be provided to the batteries. The inner-loop robust controllers utilize state feedback with integral action in the dq-synchronous frame. A linear matrix inequality-based optimization scheme is used to determine stabilizing gains of the controllers to maximize the convergence rate to steady state in the presence of uncertainties. The uncertainties of the system are described as the potential variation range of the inductance and resistance in the L-filter.

Keywords