Biology of Sport (Jul 2012)
RELATIVE AND ABSOLUTE RELIABILITY OF KARATE SPECIFIC AEROBIC TEST (KSAT) IN EXPERIENCED MALE ATHLETES
Abstract
The present investigation was conducted to evaluate the relative and absolute reliability and the minimal detectable change (MDC95% of the karate specific aerobic test (KSAT) in male karate athletes. Sixteen subjects (age: 22.2±3.7 years, height: 175.7±6.7 cm, body mass: 72.7±7.2 kg and karate experience: 9.2±4.5 years) participated in this study and performed the KSAT twice (test-retest). Reliability of time to exhaustion (TE) was very good, with intraclass correlation coefficient ICC(3.1)>0.90, standard errors of measurement SEM0.05). Effect size for all variables was dz≤0.2, rated as trivial. Thus, when using the present test as a measure of aerobic fitness, a change greater than 9.4%(81.42 s) is necessary to be confident (at the 95% level) that the change in time to exhaustion reflects improvement and exceeds the measurement error. The KSAT is a reliable tool that can be used by practitioners for assessing aerobic fitness in experienced karate athletes.