Folia Medica
(Dec 2018)
Accuracy of Different Apex Locators in Teeth with Simulated Apical Root Resorption: an In Vitro Study
Jadhav Ganesh Ranganath,
Mittal Priya,
Patil Vishal,
Kandekar Prashant,
Kulkarni Anish,
Shinde Siddharth,
Syed Shibli,
Elahi Saina
Affiliations
Jadhav Ganesh Ranganath
Department of Conservative Dentistry and Endodontics, Sinhgad Dental College & Hospital, Pune, India
Mittal Priya
Private Practitioner, Pune, India
Patil Vishal
Department of Conservative Dentistry and Endodontics, Aditya Dental College, Beed, India
Kandekar Prashant
Department of Oral and Maxillofacial Pathology, Ibn Sina National College for Medical Studies, Jeddah, India
Kulkarni Anish
Private Practitioner, Pune, India
Shinde Siddharth
Department of Orthodontics, BVDU Dental College and Hospital, Pune, India
Syed Shibli
Private Practitioner, Pune, India
Elahi Saina
Department of Periodontology, MA Rangoonwala Dental College, Pune
DOI
https://doi.org/10.2478/folmed-2018-0033
Journal volume & issue
Vol. 60,
no. 4
pp.
624
– 631
Abstract
Read online
Background: Accurate working length (WL) determination is necessary in achieving optimal healing by non-surgical root canal therapy in teeth with inflammatory apical root resorption. Electronic apex locators (EALs) are one of the mainstays in determination of WL of teeth.