Pulmonary Medicine (Jan 2012)

Delineating a Retesting Zone Using Receiver Operating Characteristic Analysis on Serial QuantiFERON Tuberculosis Test Results in US Healthcare Workers

  • Wendy Thanassi,
  • Art Noda,
  • Beatriz Hernandez,
  • Jeffery Newell,
  • Paul Terpeluk,
  • David Marder,
  • Jerome A. Yesavage

DOI
https://doi.org/10.1155/2012/291294
Journal volume & issue
Vol. 2012

Abstract

Read online

Objective. To find a statistically significant separation point for the QuantiFERON Gold In-Tube (QFT) interferon gamma release assay that could define an optimal “retesting zone” for use in serially tested low-risk populations who have test “reversions” from initially positive to subsequently negative results. Method. Using receiver operating characteristic analysis (ROC) to analyze retrospective data collected from 3 major hospitals, we searched for predictors of reversion until statistically significant separation points were revealed. A confirmatory regression analysis was performed on an additional sample. Results. In 575 initially positive US healthcare workers (HCWs), 300 (52.2%) had reversions, while 275 (47.8%) had two sequential positive tests. The most statistically significant (Kappa = 0.48, chi-square = 131.0, P<0.001) separation point identified by the ROC for predicting reversion was the tuberculosis antigen minus-nil (TBag-nil) value at 1.11 International Units per milliliter (IU/mL). The second separation point was found at TBag-nil at 0.72 IU/mL (Kappa = 0.16, chi-square = 8.2, P<0.01). The model was validated by the regression analysis of 287 HCWs. Conclusion. Reversion likelihood increases as the TBag-nil approaches the manufacturer's cut-point of 0.35 IU/mL. The most statistically significant separation point between those who test repeatedly positive and those who revert is 1.11 IU/mL. Clinicians should retest low-risk individuals with initial QFT results < 1.11 IU/mL.