Regional biaxial mechanical data of the mitral and tricuspid valve anterior leaflets
Devin Laurence,
Colton Ross,
Samuel Jett,
Cortland Johns,
Allyson Echols,
Ryan Baumwart,
Rheal Towner,
Jun Liao,
Pietro Bajona,
Yi Wu,
Chung-Hao Lee
Affiliations
Devin Laurence
Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
Colton Ross
Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
Samuel Jett
Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
Cortland Johns
Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
Allyson Echols
Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
Ryan Baumwart
Center for Veterinary Health Sciences, Oklahoma State University, Stillwater, OK 74078, USA
Rheal Towner
Advanced Magnetic Resonance Center, MS 60, Oklahoma Medical Research Foundation, Oklahoma City, OK 73104, USA
Jun Liao
Department of Bioengineering, The University of Texas at Arlington, Arlington, TX 76019, USA
Pietro Bajona
Department of Cardiovascular and Thoracic Surgery, The University of Texas Southwestern Medical Center, Dallas, TX 75390, USA
Yi Wu
Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA
Chung-Hao Lee
Biomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK 73019, USA; Institute for Biomedical Engineering, Science and Technology (IBEST), The University of Oklahoma, Norman, OK 73019, USA; Corresponding author. School of Aerospace and Mechanical Engineering, Affiliated Faculty Member, Institute for Biomedical Engineering, Science, and Technology, The University of Oklahoma, 865 Asp Ave., Felgar Hall Rm. 219C, Norman OK 73019-3609 USA.
The collective data associated with this article presents the biaxial mechanical behavior for six smaller, delimited regions of the mitral valve and tricuspid valve anterior leaflets. Each data set consists of five columns of data, specifically: (i) biaxial testing protocol ID, (ii) circumferential stretch, (iii) radial stretch, (iv) circumferential membrane tension, and (v) radial membrane tension. For further elaboration regarding methodologies or results of the biaxial mechanical characterization please refer to the companion article Laurence, 2019. Keywords: Biaxial mechanical testing, Regionally-varied mechanical properties, Atrioventricular heart valve biomechanics