Energies (Jun 2022)

Semi-3D Analysis of a Permanent Magnet Synchronous Generator Considering Bolting and Overhang Structure

  • Ji-Su Hong,
  • Hoon-Ki Lee,
  • Junghyo Nah,
  • Kyong-Hwan Kim,
  • Kyung-Hun Shin,
  • Jang-Young Choi

DOI
https://doi.org/10.3390/en15124374
Journal volume & issue
Vol. 15, no. 12
p. 4374

Abstract

Read online

This study deals with the characteristic analysis of a permanent magnet synchronous generator (PMSG) with a bolting and an overhang structure. Bolting is applied to a PMSG to prevent the defects caused by scattering. To compensate the flux reduction caused by the end effect and bolting material, an overhang structure is used for the permanent magnet machine. Therefore, an overhang structure must be considered in the three-dimensional (3D) analysis of a PMSG; however, such an analysis is time-intensive. To reduce the initial analysis time, we performed a semi-3D analysis of a PMSG considering a bolting and an overhang structure. Subsequently, we compared the output results of the characteristic analysis with a 3D finite element method and experimental results under loading.

Keywords