CJC Open (Nov 2020)

Deployment of a Covered Stent for Left Internal Mammary Perforation From Percutaneous Pacemaker ImplantationNovel Teaching Points

  • Karen Ho, MD,
  • Rajesh Patel, MD, FRCPC,
  • Payam Dehghani, MD, FRCPC

Journal volume & issue
Vol. 2, no. 6
pp. 708 – 710

Abstract

Read online

A 79-year-old woman developed a hemothorax 2 days after implantation of a permanent pacemaker. Computed tomography angiography revealed active extravasation from the left internal mammary artery. A covered stent was deployed to manage the arterial perforation. This case report explores different venous access techniques to minimize the risk of arterial injuries and describes the use of a covered stent in managing a non-grafted left internal mammary artery injury from a pacemaker implantation procedure. Résumé: Une femme de 79 ans a présenté un hémothorax deux jours après l’implantation d’un stimulateur cardiaque permanent. Une angiographie par tomodensitométrie a mis en évidence une extravasation active à partir de l’artère mammaire interne gauche. Une endoprothèse couverte a été déployée pour la prise en charge de la perforation artérielle. Ce cas porte sur l’utilisation de diverses techniques d’accès veineux pour réduire au minimum le risque de lésions artérielles, et décrit l’utilisation d’une endoprothèse couverte pour la prise en charge d’une lésion de l’artère mammaire interne gauche non greffée découlant de l’implantation d’un stimulateur cardiaque.