Scientific Reports (Sep 2022)
Numerical investigation on functional limitations of the anti-stall fin for an axial fan: one-factor analyses
Abstract
Abstract The stall in an axial fan is directly related to detrimental phenomena such as performance degradation, vibration, noise, and flow instability at low flow rates. As a kind of passive control method to handle the stall, two-dimensional plates so-named anti-stall fin (ASF) were suggested by ourselves and were attached inside the casing. In this study, the ASF's effect on the internal flow pattern was visually investigated in the flow passage, and its tendency was discussed with the performance curve. Subsequently, the ASF's functional limitations for various design parameters, which the ASF can derive aerodynamically, were presented as the primary focus of this study. Each one-factor analysis was performed, and the internal flow pattern was observed in parallel at the point where the ASF lost its function. For the radial length, axial length, number of fins, and positive-tangential angle, the ASF almost retained its function up to the limitation to prevent instability but radically lost its function at a certain flow rate. For the axial gap and negative-tangential angle, the ASF gradually lost its function. Mostly, this study was based on numerical analysis, and the performance was validated through experimental tests.