Frontiers in Cardiovascular Medicine (Jun 2022)

A Randomized Comparison of the Healing Response Between the Firehawk Stent and the Xience Stent in Patients With ST-Segment Elevation Myocardial Infarction at 6 Months of Follow-Up (TARGET STEMI OCT China Trial): An Optical Coherence Tomography Study

  • Yuan He,
  • Rutao Wang,
  • Rutao Wang,
  • Rutao Wang,
  • Jianzheng Liu,
  • Fei Li,
  • Jiayi Li,
  • Chengxiang Li,
  • Jingyu Zhou,
  • Zhijing Zhao,
  • Wangwei Yang,
  • Fangjun Mou,
  • Jing Wang,
  • Jing Kan,
  • Xiaobo Li,
  • Yan Li,
  • Ming Zheng,
  • Shaoliang Chen,
  • Chao Gao,
  • Chao Gao,
  • Chao Gao,
  • Ling Tao

DOI
https://doi.org/10.3389/fcvm.2022.895167
Journal volume & issue
Vol. 9

Abstract

Read online

BackgroundThe healing response of the Firehawk stent in patients with ST-segment elevation myocardial infarction (STEMI) remains unclear.AimWe compared the vascular healing of a biodegradable polymer sirolimus-eluting stent (Firehawk) vs. a durable polymer everolimus-eluting stent (Xience) at 6 months after percutaneous coronary intervention (PCI) in patients with STEMI.MethodsIn this prospective, multicenter, randomized, non-inferiority study, patients within 12 h of STEMI onset were randomized in a ratio of 1:1 to receive Firehawk or Xience stents. Optical coherence tomography (OCT) follow-up was performed 6 months after the index procedure and assessed frame by frame. The primary endpoint was the neointimal thickness (NIT) at 6 months evaluated by OCT. The safety endpoint was target lesion failure (TLF) at 12 months.ResultsThe Firehawk stent was non-inferior to the Xience stent in terms of the neointimal thickness (73.03 ± 33.30 μm vs. 78.96 ± 33.29 μm; absolute difference: −5.94 [one-sided 95% lower confidence bound: −23.09]; Pnon−inferiority < 0.001). No significant difference was observed between the Firehawk and Xience groups regarding the percentage of uncovered struts (0.55 [0.08, 1.32]% vs. 0.40 [0.21, 1.19]%, P = 0.804), the percentage of malapposed struts (0.17 [0.00, 1.52]% vs. 0.17 [0.00, 0.69]%, P = 0.662), and the healing score (1.56 [0.23, 5.74] vs. 2.12 [0.91, 3.81], P = 0.647). At 12 months, one patient in the Firehawk group experienced a clinically indicated target lesion revascularization. No other TLF events occurred in both groups. Independent risk factors of the NIT included body mass index, hyperlipidemia, B2/C lesions, thrombus G3–G5, thrombus aspiration, and postdilation pressure.ConclusionIn patients with STEMI, Firehawk was non-inferior to Xience in vascular healing at 6 months. Both stents exhibited nearly complete strut coverage, moderate neointimal formation, and minimal strut malapposition.Clinical Trial NumberNCT04150016.

Keywords