Journal of NeuroEngineering and Rehabilitation (Jul 2020)

Robotic tests for position sense and movement discrimination in the upper limb reveal that they each are highly reproducible but not correlated in healthy individuals

  • Catherine R. Lowrey,
  • Benett Blazevski,
  • Jean-Luc Marnet,
  • Helen Bretzke,
  • Sean P. Dukelow,
  • Stephen H. Scott

DOI
https://doi.org/10.1186/s12984-020-00721-2
Journal volume & issue
Vol. 17, no. 1
pp. 1 – 13

Abstract

Read online

Abstract Background Robotic technologies for neurological assessment provide sensitive, objective measures of behavioural impairments associated with injuries or disease such as stroke. Previous robotic tasks to assess proprioception typically involve single limbs or in some cases both limbs. The challenge with these approaches is that they often rely on intact motor function and/or working memory to remember/reproduce limb position, both of which can be impaired following stroke. Here, we examine the feasibility of a single-arm Movement Discrimination Threshold (MDT) task to assess proprioception by quantifying thresholds for sensing passive limb movement without vision. We use a staircase method to adjust movement magnitude based on subject performance throughout the task in order to reduce assessment time. We compare MDT task performance to our previously-designed Arm Position Matching (APM) task. Critically, we determine test-retest reliability of each task in the same population of healthy controls. Method Healthy participants (N = 21, age = 18–22 years) completed both tasks in the End-Point Kinarm robot. In the MDT task the robot moved the dominant arm left or right and participants indicated the direction moved. Movement displacement was systematically adjusted (decreased after correct answers, increased after incorrect) until the Discrimination Threshold was found. In the APM task, the robot moved the dominant arm and participants “mirror-matched” with the non-dominant arm. Results Discrimination Threshold for direction of arm displacement in the MDT task ranged from 0.1–1.3 cm. Displacement Variability ranged from 0.11–0.71 cm. Test-retest reliability of Discrimination Threshold based on ICC confidence intervals was moderate to excellent (range, ICC = 0.78 [0.52–0.90]). Interestingly, ICC values for Discrimination Threshold increased to 0.90 [0.77–0.96] (good to excellent) when the number of trials was reduced to the first 50. Most APM parameters had ICC’s above 0.80, (range, ICC = [0.86–0.88]) with the exception of variability (ICC = 0.30). Importantly, no parameters were significantly correlated across tasks as Spearman rank correlations across parameter-pairings ranged from − 0.27 to 0.30. Conclusions The MDT task is a feasible and reliable task, assessing movement discrimination threshold in ~ 17 min. Lack of correlation between the MDT and a position-matching task (APM) indicates that these tasks assess unique aspects of proprioception that are not strongly related in young, healthy individuals.