Compression performance and bearing capacity calculation model of small-eccentricity columns strengthened with textile-reinforced mortar (TRM)

  • S. P. Yin,
  • X. Q. Hu,
  • Y. T. Hua

DOI
https://doi.org/10.3989/mc.2019.08418
Journal volume & issue
Vol. 69, no. 335
pp. e195 – e195

Abstract

Read online

To study the compression performance of TRM-strengthened columns with small eccentricities, a total of 9 reinforced concrete (RC) columns with end corbels were subjected to compression testing. The test parameters are as follows: the number of textile layers, the ratio of longitudinal reinforcement, and polyvinyl alcohol (PVA) short-cut fiber volume fraction. The experimental results indicated that, compared to the control, columns with three layers of textile exhibited an approximately 10.66% increase in the bearing capacity. However, the effect increased only slightly when the number of textile layers increased to 4. Besides, the effect was improved with the increase in the ratio of longitudinal reinforcement and PVA fiber volume fraction. Finally, based on laboratory tests and related research results, a model for calculating normal section bearing capacity of TRM-strengthened columns with small eccentricities was presented. A comparison of the theoretical and experimental data demonstrated the applicability of the proposed model.