PLoS ONE (Jan 2013)

Quasi-monopolar stimulation: a novel electrode design configuration for performance optimization of a retinal neuroprosthesis.

  • Gita Khalili Moghadam,
  • Robert Wilke,
  • Gregg J Suaning,
  • Nigel H Lovell,
  • Socrates Dokos

DOI
https://doi.org/10.1371/journal.pone.0073130
Journal volume & issue
Vol. 8, no. 8
p. e73130

Abstract

Read online

In retinal neuroprostheses, spatial interaction between electric fields from various electrodes - electric crosstalk - may occur in multielectrode arrays during simultaneous stimulation of the retina. Depending on the electrode design and placement, this crosstalk can either enhance or degrade the functional characteristics of a visual prosthesis. To optimize the device performance, a balance must be satisfied between the constructive interference of crosstalk on dynamic range and power consumption and its negative effect on artificial visual acuity. In the present computational modeling study, we have examined the trade-off in these positive and negative effects using a range of currently available electrode array configurations, compared to a recently proposed stimulation strategy - the quasi monopolar (QMP) configuration - in which the return current is shared between local bipolar guards and a distant monopolar electrode. We evaluate the performance of the QMP configuration with respect to the implantation site and electrode geometry parameters. Our simulation results demonstrate that the beneficial effects of QMP are only significant at electrode-to-cell distances greater than the electrode dimensions. Possessing a relatively lower activation threshold, QMP was found to be superior to the bipolar configuration in terms of providing a relatively higher visual acuity. However, the threshold for QMP was more sensitive to the topological location of the electrode in the array, which may need to be considered when programming the manner in which electrode are simultaneously activated. This drawback can be offset with a wider dynamic range and lower power consumption of QMP. Furthermore, the ratio of monopolar return current to total return can be used to adjust the functional performance of QMP for a given implantation site and electrode parameters. We conclude that the QMP configuration can be used to improve visual information-to-stimulation mapping in a visual prosthesis, while maintaining low power consumption.