Recycling (Nov 2023)

X-ray Fluorescence Analysis of Waste Sm-Co Magnets: A Rational Approach

  • Alexandra Alexandrovna Arkhipenko,
  • Galina Evgenievna Marina,
  • Marina Sergeevna Doronina,
  • Natalya Alexandrovna Korotkova,
  • Vasilisa Borisovna Baranovskaya

DOI
https://doi.org/10.3390/recycling8060084
Journal volume & issue
Vol. 8, no. 6
p. 84

Abstract

Read online

Determination of the chemical composition of waste Sm-Co magnets is required for their efficient recycling. The non-stereotypical composition of said magnets makes an analysis extremely challenging. X-ray fluorescence spectrometry is a promising analytical tool for this task. It offers high accuracy and simplicity of sample preparation as it does not require sample dissolution. However, a serious limitation of X-ray fluorescence analysis is the spectral interference of matrix elements and impurities. In this work, a two-stage technique has been developed for the determination of the main components (Sm, Co) and impurities (Fe, Cu, Zr, Hf, Ti, Ni, Mn, Cr) in samples of spent samarium–cobalt magnets using wavelength dispersive X-ray fluorescence spectrometry. In order to overcome the main limitation of the chosen method and to maximize its capabilities of qualitative and quantitative analysis, we propose an approach to the selection of analytical lines and experimental conditions, as well as a preparation method for the calibration standards. The obtained results have been shown to have a good correlation with ICP-OES. The limits of detection are in the range of 0.001–0.02 wt%, and the limits of quantification are 0.003–0.08 wt%.

Keywords