Duty cycle modulation - fuzzy logic technique to track the maximum power point of a solar-wind hybrid Source
Abstract
In this article, we propose a strategy for finding the maximum power point (MPP) of a hybrid plant (solar and wind), in order to maximize the power extracted from this production plant. This strategy exploits the perturbation and observation method, based on fuzzy logic coupled with the Duty Cycle Modulator (DCM). The main objective of this study is to extract the maximum power from this hybrid power plant, while ensuring the precision and speed of convergence towards this point of maximum power. This method, tested under the Matlab / Simulink environment for a 160 kW hybrid power plant, gave results that we compared to those obtained with the Fuzzy - PWM (Pulse Width Modulator) strategy. It emerges that the Fuzzy-DCM strategy gives better precision (around 2.6 times) and a speed (around 2 times) of convergence compared to the Fuzzy-PWM strategy.