Journal of Pharmacy and Bioallied Sciences (Jan 2023)

Assessment of metal ions levels in blood of dental implant patients

  • Vivek Sharma,
  • Sneh Agrawal,
  • Deepak Sharma,
  • Rohit Thorat,
  • Reema Srichand,
  • Pranita Dalave

DOI
https://doi.org/10.4103/jpbs.jpbs_47_23
Journal volume & issue
Vol. 15, no. 6
pp. 913 – 915

Abstract

Read online

Background: Dental implants use has significantly increased and the concentration of metal ions into blood may have detrimental effect of human body. The present study aimed to determine metal ions levels in blood of dental implants patients. Materials and Methods: 48 patients scheduled for dental implant surgery was assessed for measurement of titanium and aluminum pre-operatively and post-operatively at 6 weeks, 3 months, 6 months, and 1 year. Results: Out of 48 patients, males were 22 (45.8%), and females were 26 (54.2%). The mean ± SD titanium metal levels in blood pre-operatively was 2.34 ± 0.47 mg/dl, at 6 weeks was 2.35 ± 0.48 mg/dl, at 3 months was 2.37 ± 0.52 mg/dl, at 6 months was 2.37 ± 0.42 mg/dl, and at 1 year was 2.38 ± 0.51 mg/dl. A non-significant difference was seen (P > 0.05). The mean ± SD aluminum metal levels in blood pre-operatively was 4.4 ± 0.12 mg/dl, at 6 weeks was 4.45 ± 0.14 mg/dl, at 3 months was 4.7 ± 0.13 mg/dl, at 6 months was 4.7 ± 0.21 mg/dl, and at 1 year was 4.8 ± 0.17 mg/dl. A non-significant difference was seen (P > 0.05). Conclusion: A non- significant increase in titanium and aluminum ions level in blood of patients receiving dental implants was observed.

Keywords