Background Timely lab results are important to clinical decision-making and hospital flow. However, at our institution, unreliable blood sample collection for patients with central venous access jeopardised this outcome and created staff dissatisfaction.Methods A multidisciplinary team of nurses including a specialist clinical nurse leader (CNL), the hospital intravenous team and quality improvement (QI) consultants aimed to achieve >80% blood sample collection reliability among patients with central venous access by employing a simple signature/countersignature form coupled with audit-feedback and behavioural economics strategies. The form was piloted on one 25-bed unit. Data were collected for 60 weeks and interpreted per standard run chart rules.Results Blood sample collection reliability exceeded the 80% goal by week 22. The practice was sustained on the pilot unit and spread successfully to other wards despite significant operational threats including the COVID-19 pandemic.Conclusions At our institution, a simple signature/countersignature form supplemented by audit-feedback and behavioural economics strategies led to sustained practice change among staff. The pairing of CNL to QI consultant enhanced change potency and durability.