PLoS ONE (Jan 2023)

Continuous glucose monitoring in acute ischemic stroke patients treated with endovascular therapy: A pilot study to assess feasibility and accuracy.

  • C J B A Kersten,
  • A A M Zandbergen,
  • M J Fokkert,
  • R J Slingerland,
  • H M den Hertog

DOI
https://doi.org/10.1371/journal.pone.0280153
Journal volume & issue
Vol. 18, no. 2
p. e0280153

Abstract

Read online

IntroductionHyperglycemia is common in acute ischemic stroke and is associated with larger infarct volume and unfavorable functional outcome, also in patients who undergo reperfusion therapy. Hyperglycemia during reperfusion may be a therapeutic target. However, previous randomized trials on the effect of glucose lowering in the acute phase of ischemic stroke failed to demonstrate effects on clinical outcome. Inaccurate glucose measurements and not focussing on patients who undergo reperfusion therapy are possible explanations. Our aim was to study the feasibility and accuracy of continuous glucose monitoring (CGM) in patients with acute ischemic stroke undergoing endovascular treatment (EVT).MethodsAll consecutive patients with ischemic stroke and large vessel occlusion (LVO) of the anterior circulation who were eligible for endovascular therapy within 24 hours of symptom onset and presenting at the emergency department of Isala Hospital Zwolle, the Netherlands, were enrolled in this study. CGM was performed using a Freestyle Libre Flash 2 device (FSL-CGM, Abbot Diabetes Care, Alameda, California, USA) which was implanted on arrival at the emergency department. Feasibility was defined as the number of patients who could be registered for 24 hours and delay in door-to-groin time because of sensor implantation. Accuracy of CGM versus capillary and venous based plasma glucose values was determined with the Parkes error grid analysis.ResultsTwenty-three patients were included of whom 20 completed 24 hours monitoring (87%). One patient did not give permission to use the data; one sensor broke during implantation and one meter was broken after a sensor was shot in so no measurements could be recorded. There was no significant delay in treatment due to implantation of the sensor and no adverse events. One hundred percent of CGM data are in zones A and B of the Parkes error grid analysis so data out of the sensor can be interpreted as accurate.ConclusionIn this study, we showed that continuous glucose monitoring in patients with acute ischemic stroke due to large vessel occlusion of the anterior circulation in patients who were treated with endovascular therapy is feasible, safe and accurate.