Underground Space (Apr 2024)

Investigation and measurement of old building response to the overlapped shield tunnel of multiple schemes in the sandy cobble stratum

  • Xue Li,
  • Aopeng Geng

Journal volume & issue
Vol. 15
pp. 260 – 274

Abstract

Read online

Ground movements due to tunneling are becoming increasingly critical as buildings are located around construction sites. This study proposes a new combined reinforcement method using a foundation grouting oblique pipe roof. The former improves the bearing capacity of the subsoil, and the latter blocks the transmission of soil deformation, which weakens the influence of construction during overlapped tunnel under-crossing. Based on this new method, a case study of the shield tunneling response to an old building in Line 6 of China’s Chengdu Metro is presented. Additionally, three-dimensional numerical models without reinforcement, traditional foundation grouting reinforcement, and the new combined reinforcement schemes were compared. The numerical simulation performance was verified using a set of field instrumentation data, which demonstrated that the old building response to the overlapped tunnels was under control, and the maximum deformation, angular distortion, and principal tensile strain of the building were 5.25 mm, 5.10 × 10–6 rad/m, and 0.0081%, respectively. Compared with the traditional reinforcement scheme, the deformation, angular distortion, and principal tensile strain in the combined reinforcement scheme were reduced by 54.78%, 71.02%, and 70.22%, respectively. These results have important implications for the design and construction of shield tunnels and their response to old buildings.

Keywords